Can't find a product? Call now! 888-756-4110

Cart (0) Items

Can't find a product? Call now! 888-756-4110

The Macomb Group
Login / Register
Shop Now
  • My Account Sign in/Register
    Forgot your password?
    Register
  • Cart (0) Items
  • Shop Products
    • Pipe & Tube
    • Valves
    • Fittings & Flanges
    • Fasteners & Hangers
    • Packing, Gaskets & Seals
    • Fire Protection
    • Plumbing
    • HVAC
    • Hose & Hose Fittings
    • Tools & Safety
    • Valve Automation & Instrumentation
    • PEX - Uponor
  • Brands
  • Services
    • Energy Division
    • Fabrication Services Division
    • Fire & Fabrication Division
    • Fusion & Specialty Plastics Division
    • Gas Distribution Utilities Division
    • Government Services Division
    • Heating Division
    • Hose Division
    • Instrumentation Division
    • Insulation Division (Bondy)
    • Lined Pipe Division
    • Midstream Oil & Gas Division
    • Plumbing Division
    • Steam Products Division
    • Valve Automation Division
    • Waste Water & Water Division
  • Industries
  • Locations
  • Line Cards
  • Contact Us
Shop Now
  • Home
  • Products
  • HVAC
  • Water Heater & Accessories
  • Water Heater
  • LOCHINVAR LTN05040 50 GAL GAS FVIR WATER HEATEROLD MODEL LTN050G
Lochinvar LTN050 40
  • Lochinvar LTN050 40
  1. pin-int
  2. Tweet

LOCHINVAR LTN05040 50 GAL GAS FVIR WATER HEATEROLD MODEL LTN050G

Lochinvar LTN050 40 Residential Tall High Efficiency Natural Gas Water Heater, 50 GAL, 40000 BTU/HR

  • Manufacturer: Lochinvar LLC
  • Brand: Lochinvar
  • MGPN: LTN05040
  • MPN: LTN050 40
  • CPN:
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • Availability: loading
  • See All Availability
  • Price: loading
  • Qty Add To Cart
  • My Favorites
    Add / Remove CPN
  • 888-756-4110 888-756-4110
  • SPECIFICATIONS
  • FEATURES
  • Documents
Item Name      :      Gas Water Heater
Type      :      Residential, Tall, High Efficiency
Capacity      :      50 GAL
Fuel Type      :      Natural Gas
BTU Rating      :      40000 BTU/HR
Material      :      Glass-Lined Steel Tank
First Hour Recovery      :      84 GAL
Recovery      :      42 GPH At 90 DEG F Rise
Maximum Pressure      :      300 PSI Test, 150 PSI Working
Gas Connection      :      1/2 IN
Water Connection      :      3/4 IN
Vent Size      :      3 Or 4 IN
Diameter      :      22 IN
Height      :      63-1/2 IN
Height To Gas Connection      :      13 IN
Height To Valve Connection      :      50-1/4 IN
Height To Hot And Cold Water Connection      :      57-1/4 IN
Industry Standards      :      AHRI Certified, CSA Low Lead Content Certified, NAECA Compliant, ASHRAE/IES 90.1. Meets UBC, CEC And HUD National Codes
  • These large capacity and high efficiency models all feature an environmentally friendly low NOx burner
  • Glass lined steel tank with protective anode rod
  • High efficiency models meet ENERGY STAR® requirements
  • pdf Brochure https://macombstage.cimm2.com//ASSETS/DOCUMENTS/ITEMS/EN/Lochinvar_LTN050 40_Brochure.pdf
  • pdf Instruction/Installation Manual https://macombstage.cimm2.com//ASSETS/DOCUMENTS/ITEMS/EN/Lochinvar_LTN050 40_Instruction_Installation_Manual.pdf
  • pdf Specification Sheet https://macombstage.cimm2.com//ASSETS/DOCUMENTS/ITEMS/EN/Lochinvar_LTN050 40_Specification_Sheet.pdf
  • pdf Warranty Information https://macombstage.cimm2.com//ASSETS/DOCUMENTS/ITEMS/EN/Lochinvar_LTN050 40_Warranty_Information.pdf
  • pdf Warranty Information_1 https://macombstage.cimm2.com//ASSETS/DOCUMENTS/ITEMS/EN/Lochinvar_LTN050 40_Warranty_Information_1.pdf

Branch Availability

Branch Name Available
No Records Found

Write Review

Menu

  • Shop Products
  • Brands
  • Services
  • Industries
  • Locations
  • Line Cards
  • Contact Us
  • My Account

My Account

  • Login
  • Register

Shop Products

  • Pipe & Tube
  • Valves
  • Fittings & Flanges
  • Fasteners & Hangers
  • Packing, Gaskets & Seals
  • Fire Protection
  • Plumbing
  • HVAC
  • Hose & Hose Fittings
  • Tools & Safety
  • Valve Automation & Instrumentation
  • PEX - Uponor

Services

  • Energy Division
  • Fabrication Services Division
  • Fire & Fabrication Division
  • Fusion & Specialty Plastics Division
  • Gas Distribution Utilities Division
  • Government Services Division
  • Heating Division
  • Hose Division
  • Instrumentation Division
  • Insulation Division (Bondy)
  • Lined Pipe Division
  • Midstream Oil & Gas Division
  • Plumbing Division
  • Steam Products Division
  • Valve Automation Division
  • Waste Water & Water Division

Industries

Locations

Line Cards

Contact Us

About Us

  • About Us
  • Instructional Videos
  • Blog
  • Line Cards
  • Punchout Capabilities

Customer Service

  • Brands
  • FAQ
  • Services
  • Tools

Contact Us

  • Contact Us
  • Careers
  • Subscribe to Our Blog
  • Locations
  • Will Call Counter Info

HeadQuarters

  • 6600 East 15 Mile Road
    Sterling Heights, MI 48312
  • Phone: (586) 274-4100
    Fax: (586) 274-4125
  • Phone: (586) 274-4100
    Fax: (586) 274-4125
  • Call the location nearest you
  • 24/7 Emergency: (586) 693-6236
  • 24/7 Emergency: (586) 693-6236
SIGN UP FOR THE LATEST NEWS Subscribe
NoImage NoImage NoImage

Copyright © The Macomb Group. All Rights Reserved.

Notice: This website may contain AI generated content

  • NoImage
  • NoImage
  • NoImage
  • NoImage
  • Terms of Sale
  • Terms of Use
  • Privacy Policy
  • DMCA Policy
  • Sitemap

Sign In

Forgot your password?
Sign Up

Warning

We may not be able to fulfill this item.

Please call 888-756-4110 for availability.

My Cart

Item(s)
NoImage

MGPN:

MPN:

Qty:

Lead Time: loading

View Cart Continue to Shop
loading

Contact email address is missing from your account.
Please enter your email address and click update.